Internet DRAFT - draft-ietf-teas-pce-central-control
draft-ietf-teas-pce-central-control
TEAS Working Group A. Farrel, Ed.
Internet-Draft Juniper Networks
Intended status: Informational Q. Zhao, Ed.
Expires: March 8, 2018 R. Li
Huawei Technologies
C. Zhou
Cisco Systems
September 4, 2017
An Architecture for Use of PCE and PCEP in a Network with Central
Control
draft-ietf-teas-pce-central-control-05
Abstract
The Path Computation Element (PCE) is a core component of Software
Defined Networking (SDN) systems. It can compute optimal paths for
traffic across a network and can also update the paths to reflect
changes in the network or traffic demands.
PCE was developed to derive paths for MPLS Label Switched Paths
(LSPs) supplying them to the head end of the LSP using the Path
Computation Element Communication Protocol (PCEP).
SDN has a broader applicability than signaled MPLS traffic engineered
networks, and the PCE may be used to determine paths in a range of
use cases including static LSPs, segment routing, service function
chaining, and most forms of routed or switched network. It is,
therefore, reasonable to consider PCEP as a control protocol for use
in these environments to allow the PCE to be fully enabled as a
central controller.
This document briefly introduces the architecture for PCE as a
central controller, examines the motivations and applicability for
PCEP as a control protocol in this environment, and introduces the
implications for the protocol. A PCE-based central controller can
simplify the processing of distributed control plane by blending it
with elements of SDN and without necessarily completely replacing it.
This document does not describe use cases in detail and does not
define protocol extensions: that work is left for other documents.
Status of This Memo
This Internet-Draft is submitted in full conformance with the
provisions of BCP 78 and BCP 79.
Farrel, et al. Expires March 8, 2018 [Page 1]
Internet-Draft PCE-CC Architecture September 2017
Internet-Drafts are working documents of the Internet Engineering
Task Force (IETF). Note that other groups may also distribute
working documents as Internet-Drafts. The list of current Internet-
Drafts is at http://datatracker.ietf.org/drafts/current/.
Internet-Drafts are draft documents valid for a maximum of six months
and may be updated, replaced, or obsoleted by other documents at any
time. It is inappropriate to use Internet-Drafts as reference
material or to cite them other than as "work in progress."
This Internet-Draft will expire on March 8, 2018.
Copyright Notice
Copyright (c) 2017 IETF Trust and the persons identified as the
document authors. All rights reserved.
This document is subject to BCP 78 and the IETF Trust's Legal
Provisions Relating to IETF Documents
(http://trustee.ietf.org/license-info) in effect on the date of
publication of this document. Please review these documents
carefully, as they describe your rights and restrictions with respect
to this document. Code Components extracted from this document must
include Simplified BSD License text as described in Section 4.e of
the Trust Legal Provisions and are provided without warranty as
described in the Simplified BSD License.
Table of Contents
1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . 3
2. Architecture . . . . . . . . . . . . . . . . . . . . . . . . 4
2.1. Resilience and Scaling . . . . . . . . . . . . . . . . . 7
2.1.1. Partitioned Network . . . . . . . . . . . . . . . . . 8
2.1.2. Multiple Parallel Controllers . . . . . . . . . . . . 9
2.1.3. Hierarchical Controllers . . . . . . . . . . . . . . 12
3. Applicability . . . . . . . . . . . . . . . . . . . . . . . . 13
3.1. Technology-Oriented Applicability . . . . . . . . . . . . 14
3.1.1. Applicability to Control Plane Operated Networks . . 14
3.1.2. Static LSPs in MPLS . . . . . . . . . . . . . . . . . 14
3.1.3. MPLS Multicast . . . . . . . . . . . . . . . . . . . 15
3.1.4. Transport SDN . . . . . . . . . . . . . . . . . . . . 15
3.1.5. Segment Routing . . . . . . . . . . . . . . . . . . . 15
3.1.6. Service Function Chaining . . . . . . . . . . . . . . 16
3.2. High-Level Applicability . . . . . . . . . . . . . . . . 16
3.2.1. Traffic Engineering . . . . . . . . . . . . . . . . . 16
3.2.2. Traffic Classification . . . . . . . . . . . . . . . 17
3.2.3. Service Delivery . . . . . . . . . . . . . . . . . . 17
4. Protocol Implications / Guidance for Solution Developers . . 18
Farrel, et al. Expires March 8, 2018 [Page 2]
Internet-Draft PCE-CC Architecture September 2017
5. Security Considerations . . . . . . . . . . . . . . . . . . . 19
6. Manageability Considerations . . . . . . . . . . . . . . . . 19
7. IANA Considerations . . . . . . . . . . . . . . . . . . . . . 20
8. Contributors . . . . . . . . . . . . . . . . . . . . . . . . 20
9. Acknowledgements . . . . . . . . . . . . . . . . . . . . . . 21
10. References . . . . . . . . . . . . . . . . . . . . . . . . . 22
10.1. Normative References . . . . . . . . . . . . . . . . . . 22
10.2. Informative References . . . . . . . . . . . . . . . . . 22
Authors' Addresses . . . . . . . . . . . . . . . . . . . . . . . 24
1. Introduction
The Path Computation Element (PCE) [RFC4655] was developed to offload
path computation function from routers in an MPLS traffic engineered
network. Since then, the role and function of the PCE has grown to
cover a number of other uses (such as GMPLS [RFC7025]) and to allow
delegated control [I-D.ietf-pce-stateful-pce] and PCE-initiated use
of network resources [I-D.ietf-pce-pce-initiated-lsp].
According to [RFC7399], Software Defined Networking (SDN) refers to a
separation between the control elements and the forwarding components
so that software running in a centralized system, called a
controller, can act to program the devices in the network to behave
in specific ways. A required element in an SDN architecture is a
component that plans how the network resources will be used and how
the devices will be programmed. It is possible to view this
component as performing specific computations to place traffic flows
within the network given knowledge of the availability of network
resources, how other forwarding devices are programmed, and the way
that other flows are routed. This is the function and purpose of a
PCE, and the way that a PCE integrates into a wider network control
system (including an SDN system) is presented in [RFC7491].
In early PCE implementations, where the PCE was used to derive paths
for MPLS Label Switched Paths (LSPs), paths were requested by network
elements (known as Path Computation Clients - PCCs) and the results
of the path computations were supplied to network elements using the
Path Computation Element Communication Protocol (PCEP) [RFC5440].
This protocol was later extended to allow a PCE to send unsolicited
requests to the network for LSP establishment
[I-D.ietf-pce-pce-initiated-lsp].
SDN has a far broader applicability than just signaled MPLS or GMPLS
traffic engineered networks. The PCE component in an SDN system may
be used to determine paths in a wide range of use cases including
static LSPs, segment routing [I-D.ietf-spring-segment-routing],
service function chaining (SFC) [RFC7665], and indeed any form of
routed or switched network. It is, therefore, reasonable to consider
Farrel, et al. Expires March 8, 2018 [Page 3]
Internet-Draft PCE-CC Architecture September 2017
PCEP as a general southbound control protocol (i.e., a control
protocol for communicating from the central controller to network
elements) for use in these environments to allow the PCE to be fully
enabled as a central controller.
This document introduces the architecture for PCE as a central
controller as an extension of the architecture described in [RFC4655]
and assumes the continued use of PCEP as the protocol used between
PCE and PCC. The document also examines the motivations and
applicability for PCEP as a southbound interface and introduces the
implications for the protocol used in this way. A PCE-based central
controller can simplify the processing of distributed control plane
by blending it with elements of SDN and without necessarily
completely replacing it.
This document does not describe use cases in detail and does not
define protocol extensions: that work is left for other documents.
2. Architecture
The architecture for the use of PCE within centralized control of a
network is based on the understanding that a PCE can determine how
connections should be placed and how resources should be used within
the network, and that the PCE can then cause those connections to be
established. Figure 1 shows how this control relationship works in a
network with an active control plane. This is a familiar view for
those who have read and understood [RFC4655] and
[I-D.ietf-pce-pce-initiated-lsp].
In this mode of operation, the central controller is asked to create
connectivity by a network orchestrator, a service manager, an
Operations Support System (OSS), a Network Management Station (NMS),
or some other application. The PCE-based controller computes paths
with awareness of the network topology, the available resources, and
the other services supported in the network. This information is
held in the Traffic Engineering Database (TED) and other databases
available to the PCE. Then the PCE sends a request using PCEP to one
of the Network Elements (NEs), and that NE uses a control plane to
establish the requested connections and reserve the network
resources.
Note that other databases (such as a database of LSPs - the LSP-DB)
might also be used, but for simplicity of illustration, just the TED
is shown.
Farrel, et al. Expires March 8, 2018 [Page 4]
Internet-Draft PCE-CC Architecture September 2017
--------------------------------------------
| Orchestrator / Service Manager / OSS / NMS |
--------------------------------------------
^
|
v
------------
| | -----
| PCE-based |<---| TED |
| Controller | -----
| |
------------
^
PCEP|
v
---- ---- ---- ----
| NE |<--------->| NE |<--->| NE |<--->| NE |
---- Signaling ---- ---- ----
Protocol
Figure 1: Architecture for Central Controller with Control Plane
Although the architecture shown in Figure 1 represents a form of SDN,
one objective of SDN in some environments is to remove the dependency
on a control plane. A transition architecture toward this goal is
presented in [RFC7491] and is shown in Figure 2. In this case,
services are still requested in the same way, and the PCE-based
controller still requests use of the network using PCEP. The main
difference is that the consumer of the PCEP messages is a Network
Controller that provisions the resources and instructs the data plane
using a Southbound Interface (SBI) that provides an interface to each
NE.
Farrel, et al. Expires March 8, 2018 [Page 5]
Internet-Draft PCE-CC Architecture September 2017
--------------------------------------------
| Orchestrator / Service Manager / OSS / NMS |
--------------------------------------------
^
|
v
------------
| | -----
| PCE-based |<---| TED |
| Controller | -----
| |
------------
^
| PCEP
v
------------
| Network |
| Controller |
/------------\
SBI / ^ ^ \
/ | | \
/ v v \
----/ ---- ---- \----
| NE | | NE | | NE | | NE |
---- ---- ---- ----
Figure 2: Architecture Including a Network Controller
The approach in Figure 2 delivers the SDN functionality but is overly
complicated and insufficiently flexible.
o The complication is created by the use of two controllers in a
hierarchical organization, and the resultant use of two protocols
in a southbound direction.
o The lack of flexibility arises from the assumed or required lack
of a control plane.
This document describes an architecture that reduces the number of
components and is flexible to a number of deployment models and use
cases. In this hybrid approach (shown in Figure 3) the network
controller is PCE-enabled and can also speak PCEP as the SBI (i.e.,
it can communicate with each node along the path using PCEP). That
means that the controller can communicate with a conventional control
plane-enabled NE using PCEP and can also use the same protocol to
program individual NEs. In this way the PCE-based controller can
Farrel, et al. Expires March 8, 2018 [Page 6]
Internet-Draft PCE-CC Architecture September 2017
control a wider range of networks and deliver many different
functions as described in Section 3.
There will be a trade-off in different application scenarios. In
some cases the use of a control plane will simplify deployment (for
example, by distributing recovery actions), and in other cases a
control plane may add operational complexity.
PCEP is essentially already capable of acting as an SBI and only
small, use case specific modifications to the protocol are needed to
support this architecture. The implications for the protocol are
discussed further in Section 4.
--------------------------------------------
| Orchestrator / Service Manager / OSS / NMS |
--------------------------------------------
^
|
v
------------
| | -----
| PCE-based |<---| TED |
| Controller | -----
| |
/------------\
PCEP / ^ ^ \
/ | | \
/ v v \
/ ---- ---- \
/ | NE | | NE | \
----/ ---- ---- \----
| NE | | NE |
---- ----
^ ---- ---- ^
:......>| NE |...| NE |<....:
Signaling Protocol ---- ----
Figure 3: Architecture for Node-by-Node Central Control
2.1. Resilience and Scaling
Systems with central controllers are vulnerable to two problems:
failure of the controller or overload of the controller. These
concerns are not unique to the use of a PCE-based controller, but
need to be addressed in this document before the PCE-based controller
Farrel, et al. Expires March 8, 2018 [Page 7]
Internet-Draft PCE-CC Architecture September 2017
architecture can be considered for use in all but the smallest
networks.
There are three architectural mechanisms that can be applied to
address these issues. The mechanisms are described separately for
clarity, but a deployment use may any combination of the approaches.
For simplicity of illustration, these three approaches are shown in
the sections that follow without a control plane. However, the
general, hybrid approach of Figure 3 is applicable in each case.
2.1.1. Partitioned Network
The first and simplest approach to handling controller overload or
scalability is to use multiple controllers, each responsible for a
part of the network. We can call the resultant areas of control
"domains" [RFC4655].
This approach is shown in Figure 4. It can clearly address some of
the scaling and overload concerns since each controller now only has
responsibility for a subset of the network elements. But this comes
at a cost because end-to-end connections require coordination between
the controllers. Furthermore, this technique does not remove the
single-point-of-failure concern even if it does reduce the impact on
the network of the failure of a single controller.
Note that PCEP is designed to work as a PCE-to-PCE protocol as well
as a PCE-to-PCC protocol, so it should be possible to use it to
coordinate between PCE-based controllers in this model.
Farrel, et al. Expires March 8, 2018 [Page 8]
Internet-Draft PCE-CC Architecture September 2017
--------------------------------------------
| Orchestrator / Service Manager / OSS / NMS |
--------------------------------------------
^ ^
| |
v v
------------ Coord- ------------
----- | | ination | | -----
| TED |--->| PCE-based |<-------->| PCE-based |<---| TED |
----- | Controller | | Controller | -----
| | :: | |
/------------ :: ------------\
/ ^ ^ :: ^ ^ \
/ | | :: | | \
| | | :: | | |
v v v :: v v v
---- ---- ---- :: ---- ---- ----
| NE | | NE | | NE | :: | NE | | NE | | NE |
---- ---- ---- :: ---- ---- ----
::
Domain 1 :: Domain 2
::
Figure 4: Multiple Controllers on a Partitioned Network
2.1.2. Multiple Parallel Controllers
Multiple controllers may be deployed where each controller is capable
of controlling all of the network elements. Thus the failure of any
one controller will not leave the network unmanageable and, in normal
circumstances, the load can be distributed across the controllers.
Multiple parallel controllers may be deployed as shown in Figure 5.
Each controller is capable of controlling all of the network elements
thus the failure of any one controller will not leave the network
unmanageable and, in normal circumstances, the load can be
distributed across the controllers. In this model, the orchestrator
(or any requester) must select a controller to consume its request.
Farrel, et al. Expires March 8, 2018 [Page 9]
Internet-Draft PCE-CC Architecture September 2017
--------------------------------------------
| Orchestrator / Service Manager / OSS / NMS |
--------------------------------------------
^ ^
| ___________________ |
| | Synchronization | |
v v v v
------------ ------------
| | ----- | |
| PCE-based |<---| TED |--->| PCE-based |
| Controller | ----- | Controller |
| |__ ...........| |
------------\ \_:__ :------------
^ ^ \___: \ .....: ^ ^
| | .....:\ \_:___ ..: :
| |__:___ \___:_ \_:___ :
| ....: | .....: | ..: | :
| : | : | : | :
v v v v v v v v
---- ---- ---- ----
| NE | | NE | | NE | | NE |
---- ---- ---- ----
Figure 5: Multiple Redundant Controllers
An alternate approach is to present the controllers as a "cluster"
that represents itself externally as a single controller as in
Figure 3 but which is actually comprised of multiple controllers.
The size of the cluster may be varied according to load in the manner
of network functions virtualization (NFV) and the cluster is
responsible for sharing load among the members of the cluster. This
approach is shown in Figure 6.
Farrel, et al. Expires March 8, 2018 [Page 10]
Internet-Draft PCE-CC Architecture September 2017
--------------------------------------------
| Orchestrator / Service Manager / OSS / NMS |
--------------------------------------------
^
|
--------------------------+-------------------------
| Controller ______________|_____________ |
| Cluster | | |
| | ___________________ | |
| | | Synchronization | | |
| v v v v |
| ------------ ----- ------------ |
| | PCE-based |<---| TED |--->| PCE-based | |
| | Controller | ----- | Controller | |
| | Instance | | Instance | |
| ------------ ------------ |
| ^ ^ |
| |____________________________| |
| | |
--------------------------+-------------------------
_____________|_____________
| | | |
v v v v
---- ---- ---- ----
| NE | | NE | | NE | | NE |
---- ---- ---- ----
Figure 6: Multiple Controllers Presented as a Cluster
To achieve full redundancy and to be able to continue to provide full
function in the event of the failure a controller, the controllers
must synchronize with each other. This is nominally a simple task if
there are just two controllers, but can actually be quite complex if
state changes in the network are not to be lost. Furthermore, if
there are more than two controllers, the synchronization between
controllers can become a hard problem.
Synchronization issues are often off-loaded as "database
synchronization" problems because distributed database packages have
already had to address these challenges, or by using a shared
database. In networking the problem may also be addressed by
collecting the state from the network (effectively using the network
as a database) using normal routing protocols such as OSPF, IS-IS,
and BGP. It should be noted that addressing the synchronization
problem through a shared database may be hiding the issues of
congestion and of a single point of failure: whole the controllers
may have been made resilient by allowing redundancy, the shared
Farrel, et al. Expires March 8, 2018 [Page 11]
Internet-Draft PCE-CC Architecture September 2017
database is still a problem and so the whole system is still
vulnerable.
2.1.3. Hierarchical Controllers
Figure 7 shows an approach with hierarchical controllers. This
approach was developed for PCEs in [RFC6805] and appears in various
SDN architectures where a "parent PCE", an "orchestrator", or "super
controller" takes responsibility for a high-level view of the network
before distributing tasks to lower level PCEs or controllers.
On its own, this approach does little to protect against the failure
of a controller, but it can make significant improvements in loading
and scaling of the individual controllers. It also offers a good way
to support end-to-end connectivity across multiple administrative or
technology-specific domains.
Note that this model can be arbitrarily recursive with a PCE-based
controller being the child of one parent PCE-based controller while
acting as the parent of another set of PCE-based controllers.
Farrel, et al. Expires March 8, 2018 [Page 12]
Internet-Draft PCE-CC Architecture September 2017
--------------------------------------------
| Orchestrator / Service Manager / OSS / NMS |
--------------------------------------------
^
|
v
------------
| Parent | -----
| PCE-based |<---| TED |
| Controller | -----
| |
------------
^ ^
| |
v :: v
------------ :: ------------
----- | | :: | | -----
| TED |--->| PCE-based | :: | PCE-based |<---| TED |
----- | Controller | :: | Controller | -----
/| | :: | |\
/ ------------ :: ------------ \
/ ^ ^ :: ^ ^ \
/ | | :: | | \
/ | | :: | | \
| | | :: | | |
v v v :: v v v
---- ---- ---- :: ---- ---- ----
| NE | | NE | | NE | :: | NE | | NE | | NE |
---- ---- ---- :: ---- ---- ----
::
Domain 1 :: Domain 2
::
Figure 7: Hierarchical Controllers
3. Applicability
This section gives a very high-level introduction to the
applicability of a PCE-based centralized controller. There is no
attempt to explain each use case in detail, and the inclusion of a
use case is not intended to suggest that deploying a PCE-based
controller is a mandatory or recommended approach. The sections
below are provided as a stimulus to discussion of the applicability
of a PCE-based controller and it is expected that separate documents
will be written to develop the use cases in which there is interest
for implementation and deployment. As described in Section 4
specific enhancements to PCEP may be needed for some of these use
Farrel, et al. Expires March 8, 2018 [Page 13]
Internet-Draft PCE-CC Architecture September 2017
cases and it is expected that the documents that develop each use
case will also address any extensions to PCEP.
The rest of this section is divided into two sub-sections. The first
approaches the question of applicability from a consideration of the
network technology. The second looks at the high-level functions
that can be delivered by using a PCE-based controller.
As previously mentioned, this section is intended to just make
suggestions. Thus the material supplied is very brief. The omission
of a use case is in no way meant to imply some limit on the
applicability of PCE-based control.
3.1. Technology-Oriented Applicability
This section provides a list of use cases based on network
technology.
3.1.1. Applicability to Control Plane Operated Networks
This mode of operation is the common approach for an active, stateful
PCE to control a traffic engineered MPLS or GMPLS network
[I-D.ietf-pce-stateful-pce]. Note that the PCE-based controller
determines what LSPs are needed and where to place them. PCEP is
used to instruct the head end of each LSP, and the head end signals
in the control plane to set up the LSP.
In this mode of operation, the PCE may construct its TED in a number
of ways as described in [RFC4655] including (but not limited to)
participating in the IGP or receiving information from a network
element via BGP-LS [RFC7752].
3.1.2. Static LSPs in MPLS
Static LSPs are provisioned without the use of a control plane. This
means that they are established using management plane or "manual"
configuration.
Static LSPs can be provisioned as explicit label instructions at each
hop on the end-to-end path LSP. Each router along the path must be
told what label forwarding instructions to program and what resources
to reserve. The PCE-based controller keeps a view of the network and
determines the paths of the end-to-end LSPs just as it does for the
use case described in Section 3.1.1, but the controller uses PCEP to
communicate with each router along the path of the end-to-end LSP.
In this case the PCE-based controller will take responsibility for
managing some part of the MPLS label space for each of the routers
that it controls, and may taker wider responsibility for partitioning
Farrel, et al. Expires March 8, 2018 [Page 14]
Internet-Draft PCE-CC Architecture September 2017
the label space for each router and allocating different parts for
different uses communicating the ranges to the router using PCEP.
3.1.3. MPLS Multicast
Multicast LSPs may be provisioned with a control plane or as static
LSPs. No extra considerations apply above those in Section 3.1.1 and
Section 3.1.2 except, of course, to note that the PCE must also
include the instructions about where the LSP branches, i.e., where
packets must be copied.
3.1.4. Transport SDN
Transport SDN (T-SDN) is the application of SDN techniques to
transport networks. In this respect a transport network is a network
built from any technology below the IP layer and designed to carry
traffic transparently in a connection-oriented way. Thus, an MPLS
traffic engineering network is a transport network although it is
more common to consider technologies such as Time Division
Multiplexing (TDM) and Optical Transport Networks (OTN).
Transport networks may be operated with or without a control plane
and may have point-to-point or point-to-multipoint connections.
Thus, all of the considerations in Section 3.1.1, Section 3.1.2, and
Section 3.1.3 apply so that the normal PCEP message allow a PCE-based
central controller to provision a transport network. It is usually
the case that additional technology-specific parameters are needed to
configure the NEs or LSPs in transport networks: parameters such as
optical characteristic. Such parameters will need to be carried in
the PCEP messages: new protocol extensions may be needed, as
described, for example,in [I-D.ietf-pce-wson-rwa-ext].
3.1.5. Segment Routing
Segment routing is described in [I-D.ietf-spring-segment-routing].
It relies on a series of forwarding instructions being placed in the
header of a packet. At each hop in the network a router looks at the
first instruction and may: continue to forward the packet unchanged;
strip the top instruction and forward the packet; or strip the top
instruction, insert some additional instructions, and forward the
packet.
The segment routing architecture supports operations that can be used
to steer packet flows in a network thus providing a form of traffic
engineering. A PCE-based controller can be responsible for computing
the paths for packet flows in a segment routing network, for
configuring the forwarding actions on the routers, and for telling
the edge routers what instructions to attach to packets as they enter
Farrel, et al. Expires March 8, 2018 [Page 15]
Internet-Draft PCE-CC Architecture September 2017
the network. These last two operations can be achieved using PCEP
and the PCE-based controller will assume responsibility for managing
the space of labels or path identifiers used to determine how packets
are forwarded.
3.1.6. Service Function Chaining
Service Function Chaining (SFC) is described in [RFC7665]. It is the
process of directing traffic in a network such that it passes through
specific hardware devices or virtual machines (known as service
function nodes) that can perform particular desired functions on the
traffic. The set of functions to be performed and the order in which
they are to be performed is known as a Service Function Chain. The
chain is enhanced with the locations at which the service functions
are to be performed to derive a Service Function Path (SFP). Each
packet is marked as belonging to a specific SFP and that marking lets
each successive service function node know which functions to perform
and to which service function node to send the packet next.
To operate an SFC network the service function nodes must be
configured to understand the packet markings and the edge nodes must
be told how to mark packets entering the network. Additionally it
may be necessary to establish tunnels between service function nodes
to carry the traffic.
Planning an SFC network requires load balancing between service
function nodes and traffic engineering across the network that
connects them. These are operations that can be performed by a PCE-
based controller, and that controller can use PCEP to program the
network and install the service function chains and any required
tunnels.
3.2. High-Level Applicability
This section provides a list of the high-level functions that can be
delivered by using a PCE-based controller.
3.2.1. Traffic Engineering
According to [RFC2702], Traffic Engineering (TE) is concerned with
performance optimization of operational networks. In general, it
encompasses the application of technology and scientific principles
to the measurement, modeling, characterization, control of Internet
traffic, and the application of such knowledge and techniques to
achieve specific performance objectives.
From a practical point of view this involves having an understanding
of the topology of the network, the characteristics of the nodes and
Farrel, et al. Expires March 8, 2018 [Page 16]
Internet-Draft PCE-CC Architecture September 2017
links in the network, and the traffic demands and flows across the
network. It also requires that actions can be taken to ensure that
traffic follows specific paths through the network.
PCE was specifically developed to address TE in an MPLS network, and
so a PCE-based controller is well suited to analyze TE problems and
supply answers that can be installed in the network using PCEP. PCEP
can be responsible for initiating paths across the network through a
control plane, or for installing state in the network node by node
such as in a Segment Routed network (see Section 3.1.5) or by
configuring IGP metrics.
3.2.2. Traffic Classification
Traffic classification is an important part of traffic engineering.
It is the process of looking at a packet to determine how it should
be treated as it is forwarded through the network. It applies in
many scenarios including MPLS traffic engineering (where it
determines what traffic is forwarded onto which LSPs), segment
routing (where it is used to select which set of forwarding
instructions to add to a packet), and service function chaining
(where it indicates along which service function path a packet should
be forwarded). In conjunction with traffic engineering, traffic
classification is an important enabler for load balancing.
Traffic classification is closely linked to the computational
elements of planning for the network functions just listed because it
determines how traffic load is balanced and distributed through the
network. Therefore, selecting what traffic classification should be
performed by a router is an important part of the work done by a PCE-
based controller.
Instructions can be passed from the controller to the routers using
PCEP. These instructions tell the routers how to map traffic to
paths or connections.
3.2.3. Service Delivery
Various network services may be offered over a network. These
include protection services (including end-to-end protection
[RFC4427], restoration after failure, and fast reroute [RFC4090]),
Virtual Private Network (VPN) service (such as Layer 3 VPNs [RFC4364]
or Ethernet VPNs [RFC7432]), or Pseudowires [RFC3985].
Delivering services over a network in an optimal way requires
coordination in the way that network resources are allocated to
support the services. A PCE-based central controller can consider
the whole network and all components of a service at once when
Farrel, et al. Expires March 8, 2018 [Page 17]
Internet-Draft PCE-CC Architecture September 2017
planning how to deliver the service. It can then use PCEP to manage
the network resources and to install the necessary associations
between those resources.
4. Protocol Implications / Guidance for Solution Developers
PCEP is a push-pull protocol that is designed to move requests and
responses between a server (the PCE) and clients (the PCCs, i.e., the
network elements). In particular, it has a message (PCInitiate
[I-D.ietf-pce-pce-initiated-lsp]) that can be sent by the PCE to
install state or cause actions at the PCC, and a response message
(PCRpt) that is used to confirm the request.
As such, there is an expectation that only relatively minor changes
to PCEP are required to support the concept of a PCE-based
controller. The only work expected to be needed is extensions to
existing PCEP messages to carry additional or specific information
elements for the individual use cases, which maintain backward
compatibility and do not impact existing PCEP deployments. [RFC5440]
already describes how legacy implementations handle unknown protocol
extensions and how to use the PCEP Open message to indicate support
for PCEP features. Where possible, consistent with the general
principles of how protocols are extended, any additions to the
protocol should be made in a generic way such that they are open to
use in a range of applications.
It is anticipated that new documents (such as
[I-D.zhao-pce-pcep-extension-for-pce-controller]) will be produced
for each use case dependent on support and demand. Such documents
will explain the use case and define the necessary protocol
extensions.
Protocol extensions could have impact on existing PCEP deployments
and the interoperability between different implementations. It is
anticipated that changes of the PCEP protocol or addition of
information elements could require additional testing to ensure
interoperability between different PCEP implementations.
It is reasonable to expect that implementations are able to select a
subset or profile of the protocol extensions and PCEP features that
are relevant for the application scenario in which they will be
deployed. Identification of these profiles should form part of the
protocol itself so that interoperability can be easily determined and
so that testing can be limited to the specific profiles.
Note that protocol mechanisms to handle synchronization of state in
parallel PCE-based controllers will also be required if parallel
controllers are used as described in Section 2.1.2. There is a
Farrel, et al. Expires March 8, 2018 [Page 18]
Internet-Draft PCE-CC Architecture September 2017
discussion of mechanisms to achieve PCE state synchronization in
[I-D.ietf-pce-stateful-pce].
5. Security Considerations
Security considerations for a PCE-based controller are little
different from those for any other PCE system. That is, the
operation relies heavily on the use and security of PCEP and so
consideration should be given to the security features discussed in
[RFC5440] and the additional mechanisms described in
[I-D.ietf-pce-pceps].
It should be observed that the trust model of a network that operates
without a control plane is different from one with a control plane.
The conventional "chain of trust" used with a control plane is
replaced by individual trust relationships between the controller and
each individual NE. This model may be considerably easier to manage
and so is more likely to be operated with a high level of security.
However, an architecture with a central controller has a central
point of failure and this is also a security weakness since the
network can be vulnerable to denial of service attacks on the
controller. Similarly, the central controller provides a focus for
interception and modification of messages sent to individual NEs. In
short, while the interactions with a PCE-based controller are not
substantially different to those in any other SDN architecture, the
security implications of SDN have not been fully discussed or
described. Therefore, protocol and applicability work around
solutions for this architecture must take proper account of these
concerns.
It is expected that each new document that is produced for a specific
use case will also include considerations of the security impacts of
the use of a PCE-based central controller on the network type and
services being managed.
6. Manageability Considerations
The architecture described in this document is a management
architecture: the PCE-based controller is a management component that
controls the network through a southbound management protocol (PCEP).
An implementation of a PCE-based controller will require access to
information about the state of the network, its nodes, and its links.
Some of this will be the TED as is normal for a PCE and can be
collected using the mechanisms already in place (such as listening to
the IGPs, using BGP-LS [RFC7752], or northbound export of YANG-
encoded data [I-D.ietf-teas-yang-te-topo] from the network elements
Farrel, et al. Expires March 8, 2018 [Page 19]
Internet-Draft PCE-CC Architecture September 2017
to the controller). More information may be collected in the LSP
database as described for stateful PCEs as described in [RFC7399] and
[I-D.ietf-pce-stateful-pce]. Additional information may be needed
for other specific use cases and will need to be collected and passed
to the controller. This may require protocol extensions for the
mechanisms listed in this paragraph.
The use of different PCEP options and protocol extensions may have an
impact on interoperability, which is a management issue. As noted in
Section 4, protocol extensions should be done in a way that makes it
possible to identify profiles of PCEP to aid interoperability and
this will aid deployment and manageability.
RFC 5440 [RFC5440] contains a substantive manageability
considerations section that examines how a PCE-based system and a
PCE-enabled system may be managed. A MIB module for PCEP was
published as RFC 7420 [RFC7420] and a YANG module for PCEP has also
been proposed [I-D.pkd-pce-pcep-yang].
7. IANA Considerations
This document makes no requests for IANA action.
8. Contributors
The following people contributed to discussions that led to the
development of this document:
Farrel, et al. Expires March 8, 2018 [Page 20]
Internet-Draft PCE-CC Architecture September 2017
Cyril Margaria
Email: cmargaria@juniper.net
Sudhir Cheruathur
Email: scheruathur@juniper.net
Dhruv Dhody
Email: dhruv.dhody@huawei.com
Daniel King
Email: daniel@olddog.co.uk
Iftekhar Hussain
Email: IHussain@infinera.com
Anurag Sharma
Email: AnSharma@infinera.com
Eric Wu
Email: eric.wu@huawei.com
9. Acknowledgements
The ideas in this document owe a lot to the work started by the
authors of [I-D.zhao-teas-pcecc-use-cases] and
[I-D.zhao-pce-pcep-extension-for-pce-controller]. The authors of
this document fully acknowledge the prior work and thank those
involved for opening the discussion. The individuals concerned are:
King Ke, Luyuan Fang, Chao Zhou, Boris Zhang, Zhenbin Li.
This document has benefited from the discussions within a small ad
hoc design team the members of which are listed as document
contributors.
Thanks to Michael Scharf and Andy Malis for a lively discussion of
this document.
Thanks to Phil Bedard, Aijun Wang, and Elwyn Davies for last call
comments on this document.
Spencer Dawkins, Adam Roach, and Ben Campbell provided helpful
comments during IESG review.
Farrel, et al. Expires March 8, 2018 [Page 21]
Internet-Draft PCE-CC Architecture September 2017
10. References
10.1. Normative References
[I-D.ietf-pce-pce-initiated-lsp]
Crabbe, E., Minei, I., Sivabalan, S., and R. Varga, "PCEP
Extensions for PCE-initiated LSP Setup in a Stateful PCE
Model", draft-ietf-pce-pce-initiated-lsp-10 (work in
progress), June 2017.
[RFC4655] Farrel, A., Vasseur, J., and J. Ash, "A Path Computation
Element (PCE)-Based Architecture", RFC 4655,
DOI 10.17487/RFC4655, August 2006, <https://www.rfc-
editor.org/info/rfc4655>.
[RFC5440] Vasseur, JP., Ed. and JL. Le Roux, Ed., "Path Computation
Element (PCE) Communication Protocol (PCEP)", RFC 5440,
DOI 10.17487/RFC5440, March 2009, <https://www.rfc-
editor.org/info/rfc5440>.
10.2. Informative References
[I-D.ietf-pce-pceps]
Lopez, D., Dios, O., Wu, Q., and D. Dhody, "Secure
Transport for PCEP", draft-ietf-pce-pceps-16 (work in
progress), August 2017.
[I-D.ietf-pce-stateful-pce]
Crabbe, E., Minei, I., Medved, J., and R. Varga, "PCEP
Extensions for Stateful PCE", draft-ietf-pce-stateful-
pce-21 (work in progress), June 2017.
[I-D.ietf-pce-wson-rwa-ext]
Lee, Y. and R. Casellas, "PCEP Extension for WSON Routing
and Wavelength Assignment", draft-ietf-pce-wson-rwa-ext-06
(work in progress), December 2016.
[I-D.ietf-spring-segment-routing]
Filsfils, C., Previdi, S., Decraene, B., Litkowski, S.,
and R. Shakir, "Segment Routing Architecture", draft-ietf-
spring-segment-routing-12 (work in progress), June 2017.
[I-D.ietf-teas-yang-te-topo]
Liu, X., Bryskin, I., Beeram, V., Saad, T., Shah, H., and
O. Dios, "YANG Data Model for TE Topologies", draft-ietf-
teas-yang-te-topo-12 (work in progress), July 2017.
Farrel, et al. Expires March 8, 2018 [Page 22]
Internet-Draft PCE-CC Architecture September 2017
[I-D.pkd-pce-pcep-yang]
Dhody, D., Hardwick, J., Beeram, V., and j.
jefftant@gmail.com, "A YANG Data Model for Path
Computation Element Communications Protocol (PCEP)",
draft-pkd-pce-pcep-yang-06 (work in progress), July 2016.
[I-D.zhao-pce-pcep-extension-for-pce-controller]
Zhao, Q., Li, Z., Dhody, D., Karunanithi, S., Farrel, A.,
and C. Zhou, "PCEP Procedures and Protocol Extensions for
Using PCE as a Central Controller (PCECC) of LSPs", draft-
zhao-pce-pcep-extension-for-pce-controller-05 (work in
progress), June 2017.
[I-D.zhao-teas-pcecc-use-cases]
Zhao, Q., Li, Z., Khasanov, B., Ke, Z., Fang, L., Zhou,
C., Communications, T., Rachitskiy, A., and A. Gulida,
"The Use Cases for Using PCE as the Central
Controller(PCECC) of LSPs", draft-zhao-teas-pcecc-use-
cases-02 (work in progress), October 2016.
[RFC2702] Awduche, D., Malcolm, J., Agogbua, J., O'Dell, M., and J.
McManus, "Requirements for Traffic Engineering Over MPLS",
RFC 2702, DOI 10.17487/RFC2702, September 1999,
<https://www.rfc-editor.org/info/rfc2702>.
[RFC3985] Bryant, S., Ed. and P. Pate, Ed., "Pseudo Wire Emulation
Edge-to-Edge (PWE3) Architecture", RFC 3985,
DOI 10.17487/RFC3985, March 2005, <https://www.rfc-
editor.org/info/rfc3985>.
[RFC4090] Pan, P., Ed., Swallow, G., Ed., and A. Atlas, Ed., "Fast
Reroute Extensions to RSVP-TE for LSP Tunnels", RFC 4090,
DOI 10.17487/RFC4090, May 2005, <https://www.rfc-
editor.org/info/rfc4090>.
[RFC4364] Rosen, E. and Y. Rekhter, "BGP/MPLS IP Virtual Private
Networks (VPNs)", RFC 4364, DOI 10.17487/RFC4364, February
2006, <https://www.rfc-editor.org/info/rfc4364>.
[RFC4427] Mannie, E., Ed. and D. Papadimitriou, Ed., "Recovery
(Protection and Restoration) Terminology for Generalized
Multi-Protocol Label Switching (GMPLS)", RFC 4427,
DOI 10.17487/RFC4427, March 2006, <https://www.rfc-
editor.org/info/rfc4427>.
Farrel, et al. Expires March 8, 2018 [Page 23]
Internet-Draft PCE-CC Architecture September 2017
[RFC6805] King, D., Ed. and A. Farrel, Ed., "The Application of the
Path Computation Element Architecture to the Determination
of a Sequence of Domains in MPLS and GMPLS", RFC 6805,
DOI 10.17487/RFC6805, November 2012, <https://www.rfc-
editor.org/info/rfc6805>.
[RFC7025] Otani, T., Ogaki, K., Caviglia, D., Zhang, F., and C.
Margaria, "Requirements for GMPLS Applications of PCE",
RFC 7025, DOI 10.17487/RFC7025, September 2013,
<https://www.rfc-editor.org/info/rfc7025>.
[RFC7399] Farrel, A. and D. King, "Unanswered Questions in the Path
Computation Element Architecture", RFC 7399,
DOI 10.17487/RFC7399, October 2014, <https://www.rfc-
editor.org/info/rfc7399>.
[RFC7420] Koushik, A., Stephan, E., Zhao, Q., King, D., and J.
Hardwick, "Path Computation Element Communication Protocol
(PCEP) Management Information Base (MIB) Module",
RFC 7420, DOI 10.17487/RFC7420, December 2014,
<https://www.rfc-editor.org/info/rfc7420>.
[RFC7432] Sajassi, A., Ed., Aggarwal, R., Bitar, N., Isaac, A.,
Uttaro, J., Drake, J., and W. Henderickx, "BGP MPLS-Based
Ethernet VPN", RFC 7432, DOI 10.17487/RFC7432, February
2015, <https://www.rfc-editor.org/info/rfc7432>.
[RFC7491] King, D. and A. Farrel, "A PCE-Based Architecture for
Application-Based Network Operations", RFC 7491,
DOI 10.17487/RFC7491, March 2015, <https://www.rfc-
editor.org/info/rfc7491>.
[RFC7665] Halpern, J., Ed. and C. Pignataro, Ed., "Service Function
Chaining (SFC) Architecture", RFC 7665,
DOI 10.17487/RFC7665, October 2015, <https://www.rfc-
editor.org/info/rfc7665>.
[RFC7752] Gredler, H., Ed., Medved, J., Previdi, S., Farrel, A., and
S. Ray, "North-Bound Distribution of Link-State and
Traffic Engineering (TE) Information Using BGP", RFC 7752,
DOI 10.17487/RFC7752, March 2016, <https://www.rfc-
editor.org/info/rfc7752>.
Authors' Addresses
Farrel, et al. Expires March 8, 2018 [Page 24]
Internet-Draft PCE-CC Architecture September 2017
Adrian Farrel (editor)
Juniper Networks
Email: afarrel@juniper.net
Quintin Zhao (editor)
Huawei Technologies
125 Nagog Technology Park
Acton, MA 01719
USA
Email: quintin.zhao@huawei.com
Robin Li
Huawei Technologies
Huawei Bld., No.156 Beiqing Road
Beijing 100095
China
Email: lizhenbin@huawei.com
Chao Zhou
Cisco Systems
Email: chao.zhou@cisco.com
Farrel, et al. Expires March 8, 2018 [Page 25]